Elkay BOQ & Project Supply in Qatar

For an Elkay BOQ Qatar enquiry, send the BOQ line item together with the specification, quantity, project name, location and required date. If the BOQ does not identify an exact model, the functional requirements should be clarified before quotation or submittal.

BOQ language is often short, while product configurations are detailed. A line such as ‘bottle filling station, complete’ may not tell procurement whether the project requires filtration, refrigeration, touchless activation, outdoor suitability, accessibility or a particular mounting arrangement.

This page is built specifically for BOQ-to-product matching and project procurement, rather than general Elkay supplier discovery.

How to Read an Elkay BOQ Line

BOQ clueProcurement question
Bottle filling stationFiller only or combination cooler/fountain?
FilteredWhich filter and capacity?
Chilled / refrigeratedWhat chilling capacity and electrical supply?
OutdoorIs the exact model manufacturer-rated for outdoor use?
ADA / accessibleWhich station arrangement and mounting requirements?
Stainless steelWhich finish/model family?
TouchlessWhich functions are sensor activated?

From Generic BOQ to Exact Model

Start with the BOQ, then cross-check the consultant specification and drawings. Confirm the installation location, expected users, water/drainage services, electrical supply, filtration, refrigeration, accessibility and finish.

Only after those items are clear should an exact model be placed into the quotation and technical submittal.

Verified Manufacturer Example

The LZSTL8WSS2K illustrates the level of detail hidden behind a short BOQ description. Elkay lists it as indoor, wall-mounted, filtered, refrigerated, bi-level ADA, stainless steel, 220V/50Hz, with two stations and an 8 GPH chilling capacity.

The manufacturer also lists BIM, CAD, specification and installation downloads. A BOQ that merely says ‘filtered bottle filling station’ is therefore not enough to assume this exact configuration.

Project Supply Schedule

FieldExample information to capture
BOQ itemHydration station / bottle filler
ModelExact Elkay model after confirmation
QuantityTotal units
LocationBuilding / floor / zone
ConfigurationFiltered, refrigerated, indoor/outdoor, etc.
Submittal statusPending / submitted / approved
Required on siteTarget date

RFQ Quality Checklist

Attach the BOQ and relevant specification pages; state whether alternatives are permitted; include project name and consultant where relevant; provide total quantity; identify delivery phasing; and state whether technical submittals are required with the quotation.

Commercial Risk Controls

Do not quote one model and submit another. Do not treat product-family marketing language as an exact specification. Do not assume every Elkay unit is 220V/50Hz. Do not claim an approval or certification unless the exact model documentation supports it.

Request a BOQ Review

Send Deluxe Plumbing Supplies the BOQ, specification, quantity and project details. The goal is to convert the commercial description into a technically defined product requirement before procurement.

Frequently Asked Questions

Can you quote an Elkay BOQ without a model?

Yes, subject to sufficient specification detail. Generic descriptions may require clarification before a suitable model can be identified.

What if the consultant specifies a discontinued model?

The current manufacturer catalogue and replacement information should be checked. Any proposed alternative should follow the project’s approval process.

Should accessories and filters be included in the BOQ review?

Yes. Compatible filters, mounting accessories and other required components should be considered with the main equipment.

Can a BOQ include multiple Elkay models?

Yes. A consolidated model-and-quantity schedule is usually more efficient for project procurement.

What should be consistent across quotation and submittal?

The exact model number and configuration should remain consistent across the commercial offer, datasheet and approval documents.