FEBCO 856ST Double Check Detector Assembly Backflow Preventer

  • Model Number: FEBCO 856ST
  • Product Type: Double Check Detector Assembly (DCDA)
  • Configuration: Inline, horizontal installation
  • Material: Lead-free cast bronze or ductile iron (model dependent)
  • Function: Backflow prevention with water use monitoring
  • Application: Ideal for fire protection systems and non-potable water lines in Qatar
  • Compliance: ASSE 1048, AWWA C510, and CSA B64.5 approved
Category Brand:

Product Description

Specification Details
Model Number FEBCO 856ST
Product Type Double Check Detector Assembly (DCDA)
Installation Type Inline horizontal installation
Material Lead-free cast bronze or ductile iron (model dependent)
Function Backflow prevention with water use monitoring
Main Application Fire protection systems and non-potable water systems
Protection Type Backpressure and backsiphonage prevention
Meter Feature Integrated bypass meter for leak and unauthorized use detection
Valve Design Dual independently acting check valves
Connection Type Flanged or grooved connection options
Construction Corrosion-resistant body
Compliance Standards ASSE 1048, AWWA C510, CSA B64.5
Serviceability Field-serviceable components with replaceable seats
Suitable Industries Commercial buildings, municipal systems, industrial facilities
Optional Feature Tamper switches for additional security

 

What is the FEBCO 856ST Double Check Detector Assembly used for?

The FEBCO 856ST is designed to protect water systems from contamination caused by reverse water flow. It combines a dual check valve assembly with a detector meter that identifies leaks and unauthorized water use. This system is widely installed in fire sprinkler systems, secondary water networks, and industrial water applications where continuous monitoring is required.

At Deluxe Plumbing Supplies, this product is commonly selected for projects requiring a reliable Backflow Preventer solution for large-scale infrastructure and commercial buildings.

How does the FEBCO 856ST prevent backflow contamination?

The assembly contains two independently operating check valves arranged in series. Water flows normally in one direction, while reverse flow immediately triggers the valves to close.

The working principle is closely related to the Double check valve concept, which uses multiple valve stages to provide additional protection against water contamination in plumbing systems.

Why is the integrated bypass meter important?

The built-in bypass meter performs two important functions:

  • Detects hidden water leaks
  • Identifies unauthorized water usage
  • Monitors low-flow activity
  • Helps facility managers track system performance
  • Supports maintenance planning

This monitoring capability makes the unit more advanced than standard valve assemblies.

Which applications are best suited for the FEBCO 856ST?

The FEBCO 856ST performs effectively in several environments:

  • Fire sprinkler systems
  • Commercial buildings
  • Municipal water systems
  • Institutional facilities
  • High-rise developments
  • Industrial processing systems
  • Secondary water distribution networks

Many engineers select this Backflow Preventer because of its suitability for medium hazard applications.

What construction materials are used in the FEBCO 856ST?

The FEBCO 856ST uses durable materials for long-term operation:

Component Material
Valve body Ductile iron or lead-free bronze
Check seats Stainless steel
Disc rubbers Replaceable rubber components
External coating Corrosion-resistant epoxy finish

These materials help improve lifespan and reduce maintenance requirements.

How does the FEBCO 856ST improve fire protection systems?

Fire protection systems require water to remain uncontaminated and available during emergencies. The FEBCO 856ST supports these systems by:

  • Preventing reverse contamination
  • Monitoring unauthorized use
  • Detecting leaks
  • Reducing pressure loss
  • Maintaining code compliance

For large fire system installations, Deluxe Plumbing Supplies frequently supplies this Backflow Preventer for safety-focused infrastructure projects.

What standards and certifications does the FEBCO 856ST meet?

The FEBCO 856ST is manufactured to comply with recognized industry requirements:

  • ASSE 1048
  • AWWA C510
  • CSA B64.5

Compliance with these standards supports reliable operation in regulated plumbing environments.

How easy is maintenance and servicing?

The system is engineered for convenient servicing without extensive disassembly.

Maintenance advantages include:

  • Replaceable seats
  • Serviceable check modules
  • Accessible test cocks
  • Independent top-entry covers
  • Minimal specialized tools required

Routine inspection helps maximize operating efficiency.

Why is corrosion resistance important in plumbing systems?

Plumbing components operate under varying environmental conditions. Corrosion-resistant materials help:

  • Extend service life
  • Reduce maintenance costs
  • Maintain flow performance
  • Prevent structural deterioration
  • Improve system reliability

This makes the FEBCO 856ST suitable for demanding environments and long-term installations.

Why buy the FEBCO 856ST from Deluxe Plumbing Supplies?

Deluxe Plumbing Supplies supplies commercial-grade plumbing and water safety products for Qatar projects requiring durability and compliance.

Customers benefit from:

  • Quality-certified products
  • Professional plumbing solutions
  • Reliable product support
  • Industry-focused supply expertise
  • Access to premium Backflow Preventer systems

 

FAQ

What is the main function of the FEBCO 856ST?

The primary function is preventing contaminated water from flowing backward into clean water systems while also detecting leaks and unauthorized water usage.

Can the FEBCO 856ST be used on potable water systems?

The unit is primarily intended for non-potable and medium hazard applications such as fire protection systems and industrial water lines.

Does the FEBCO 856ST include a leak detection system?

Yes. The integrated bypass meter identifies leaks and unauthorized water usage within the connected system.

Is the FEBCO 856ST suitable for fire sprinkler systems?

Yes. It is commonly installed in fire sprinkler and standpipe systems where monitoring and backflow protection are required.

Does the assembly require regular testing?

Yes. Routine testing and inspections are recommended to ensure proper valve performance and compliance.

What installation orientation is recommended?

The FEBCO 856ST is designed primarily for horizontal inline installation.

Are replacement parts available?

Yes. Replaceable seats, disc kits, springs, and maintenance kits are available for servicing and long-term use.